Global integrated manufacturer of intelligent explosion-proof electrical equipment with energy efficiency
4008 606 956
Explosion-proof performance conforms to
-CENELEC standard
-IEC standard
-NEC standard
Applicable to zone 1 and zone 2 zone 21 and zone 22 class II, zone 1 and zone 2 class II, zone 2, gas group A, B, C, D
Using ultra-bright LED light source, high efficiency and energy saving, with a service life of up to 50,000 hours. Integrated chip control, and has a variety of protect the circuit.
Synchronous flashing of multiple lamps can be realized through the synchronization signal line connection.
Copper-free aluminum shell, plastic sprayed surface.
Model Meaning

Technical Parameter
|
Explosion proof aviation obstruction lamp |
CN192-I-E□ |
|
Explosion proof typeGas explosion proof typeDust explosion proof type |
II2G Ex db IIC T6 GbII2D Ex tb IIIC T80℃ Db |
|
Executive standard |
GB/T 3836.1, GB/T 3836.2, GB/T 3836.31EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-31IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-31 |
|
Shell material |
Copper-free aluminum, plastic sprayed surface |
|
Glass cover |
Tempered glass, resistant to 4J impact |
|
Exposed fasteners |
Stainless steel |
|
Rated voltage |
100V, 110V, 120V, 127V, 220V, 230V, 240V AC 50/60Hz |
|
Light source specifications |
LED |
|
Light source power (W) |
≤10W (Continuous work) |
|
Bulb color |
Red |
|
Peak light intensity |
>200cd |
|
Flash frequency |
16, 20, 30, 40, 60, 80, 120, 240 (times/min) |
|
Ground protection |
M5 (Grounding screws are equipped inside and outside the lamp housing) |
|
Protection level |
IP65, IP66 |
|
Ambient temperature |
-20℃~+55℃ |
|
Terminal block |
3 x 1.5~2.5mm² (L+N+PE) |
|
Cable entry |
4 x M25 x 1.5 Plugging |
|
Cable entry device (optional) |
Recommend to use CN970-I (Ex eb) |
Wired synchronization line connection diagram

Outline diagram (all dimensions in mm)-can be modified

Note: The light is controlled by two sets of completely independent photoelectric control systems respectively, to control the main and standby lights. Usually, the main light flashes at night and turns off automatically during the day. When the main lamp is damaged, the backup lamp will automatically start to replace the main lamp.